NameDescriptionTypeAdditional information
Frequency

If the frequency is 1, the MetaVision frequency is "Set Interval", with the period and period unit defining the interval. If the frequency is higher than 1, then the MetaVision frequency depends on the periodUnit and can be either "Set doses per day" or "Set doses per week". For example, to say "every 8 hours" set the frequency to 1, the period to 8, and the unit to hours. To say "4 times per day" set the frequency to 4, the period to 1, and the periodUnit to day.

integer

None.

Period

When the frequency is 1, setting the period defines the interval, for example 8 in "1 time per 8 hours". The periodUnit must match the equivalent of minutes, hours, or days. (Half-days, seconds, weeks, etc are not supported.)

integer

None.

PeriodUnit

iMDsoft.API.Metavision.Data.Data.CodedElement

None.

TimeOfDay

This field is used for the Selected times frequency and should be expressed as a collection of times, for example "9:30,21:30"

Collection of time interval

None.