NameDescriptionTypeAdditional information
Id

The dose Guid. This Guid is the same across multiple dose instance id's

globally unique identifier

None.

DoseForm

Dose form of the medication being administered, for example "Tablet" or "Infusion bag".

iMDsoft.API.Metavision.Data.Data.CodedElement

None.

Route

Route, e.g. "IV" or "Per Os". The route the dose was planned with will be returned. If the dose has no route, null will be returned.

iMDsoft.API.Metavision.Data.Data.CodedElement

None.

Location

Location e.g. "left arm". The location the dose was planned with will be returned. If the dose has no location, null will be returned.

iMDsoft.API.Metavision.Data.Data.CodedElement

None.

StartTime

The start time the dose was planned with.

date

None.

CoSignAdministrationUser

The user who co-signed the dose for administration.

string

None.

CoSignPreparationUser

The user who co-signed the dose for preparation.

string

None.

Comments

Comments entered for the dose.

string

None.

IsSelfAdministered

Indicates whether the dose is self administered.

boolean

None.

IsPrepared

Is dose prepared

boolean

None.

Rate

The drip rate at which the medication should be administered. Whether the main component is in mass or volume unit, rate will be returned (not dose).

iMDsoft.API.Metavision.Data.Data.DripUnitNameAndValueOfSystem.Decimal

None.

InfuseOver

The duration for which the medication should be infused over.

iMDsoft.API.Metavision.Data.Data.UnitNameAndValueOfSystem.Decimal

None.

OrderComponents

List of order components. Represents the dose details grid in the Dose Entry window in MetaVision.

Collection of iMDsoft.API.Metavision.Data.Doses.DoseActionDataModels.ActionOrderComponent

None.

AttachedForms

Attached Forms

Collection of iMDsoft.API.Metavision.Data.Doses.AttachedForm

None.

ActionTime

Action time. in offline case we also support the former report not in the future.

date

None.

DbTimeStamp

Db time stamp used for checking dose is not stale

Collection of byte

None.